Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Environ Au ; 3(4): 242-248, 2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37483304

RESUMO

Products and starting materials containing volatile organic compounds (VOCs) can easily be found in a variety of businesses, making them a common source of occupational exposure. To prevent negative impacts on employee health, field industrial hygienists must conduct regular sampling to ensure exposures remain below the regulatory limits set by governmental and professional associations. As such, the need for sensitive and reliable exposure assessment techniques becomes evident. Over the preceding decade, the industrial hygiene research group at the University of Alabama at Birmingham (UAB) has been working on the development of an emerging, preanalytical technique known as photothermal desorption (PTD) to improve upon the analytical sensitivity of currently employed methods. PTD's novel design uses pulses of high-energy light to desorb analytes from thermally conductive, carbonaceous sorbents, to be delivered to downstream analytical detectors. Since PTD's conception, the theoretical framework and advances in sorbent fabrication have been investigated; however, further work is needed to produce a field-ready sampling device for use with PTD. As such, objectives of the present work were to design a PTD-compatible diffusive sampler prototype and characterize the prototype's sampling efficiencies for toluene, n-hexane, trichloroethylene, and isopropyl alcohol. In pursuit of these objectives, the study empirically quantified the sampled masses of toluene, n-hexane, trichloroethylene, and isopropyl alcohol, at occupationally relevant air concentrations, to be 12.17 ± 0.06, 8.2 ± 0.1, 3.97 ± 0.06, and 8.0 ± 0.1 mg, respectively. Moreover, the analyte sampling efficiencies were found to be 2.2 ± 0.1, 1.7 ± 0.1, 1.2 ± 0.1, and 0.51 ± 0.05 (unitless) when comparing empirically (i.e., laboratory observed) sample mass values to theoretically predicted values. The sampling efficiencies and collected sample masses reported herein demonstrate the promising design of PTD-compatible diffusive samplers. When used in conjunction with the PTD method, the prototype samplers present strong evidence for improving analytical sensitivity in exposure assessments of VOCs in the workplace.

2.
Artigo em Inglês | MEDLINE | ID: mdl-35805644

RESUMO

There are few known puff topography devices designed solely for gathering electronic cigarette puff topography information, and none made for high-powered sub-ohm devices. Ten replicate Bernoulli flow cells were designed and 3D printed. The relationship between square root of pressure difference and flow rate was determined across 0−70 L/min. One representative flow cell was used to estimate puff volume and flow rate under six simulated puffing regimes (0.710 L, 2.000 L and 3.000 L, at low and high flow rates) to determine the system's accuracy and utility of using dual pressure sensors for flow measurement. The relationship between flow rate and square root of pressure differential for the ten replicate cells was best fit with a quadratic model (R2 = 0.9991, p < 0.0001). The higher-pressure sensor was accurate at both low and high flow rates for 0.71 L (102% and 111% respectively), 2.00 L (96% and 103% respectively), and 3.00 L (100.1% and 107% respectively) but the lower-pressure sensor provided no utility, underpredicting volume and flow. This puff topography system generates very little resistance to flow, easily fits between user's atomizer and mouthpiece, and is calibrated to measure flows up to 70 L/min.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Coleta de Dados , Nebulizadores e Vaporizadores , Nicotina , Fumar
3.
J Occup Environ Hyg ; 19(5): 318-326, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35293854

RESUMO

Airborne particles play a significant role in the transmission of SARS-CoV-2, the virus that causes COVID-19. A previous study reported that institutional flush-O-meter (FOM) toilets can generate 3-12 times as many droplets as other toilets by splashing (large droplets) and bubble bursting (fine droplets). In this study, an aerosol suppression lid was evaluated to measure the reduction of particles by size using three metrics; number, surface area, and mass concentrations. To quantify toilet flush aerosol over time, detailed particle size distributions (from 0.016-19.81 µm across 152 size bins) were measured from a FOM toilet in a controlled-environment test chamber, without ventilation, with and without use of the suppression lid. Prior to each flushing trial, the toilet bowl water was seeded with 480 mL fluorescein at 10 mg/mL. A high-speed camera was used to record the large droplet movements after flushing. An ultraviolet-visible spectrophotometer was used to analyze the wipe samples to evaluate the contamination on the lid. The particle number, surface area, and mass concentrations without a lid were elevated compared to a lid in the first 90 sec. Overall, the lid reduced 48% of total number concentration, 76% of total surface area concentration, and 66% of total mass concentration, respectively. Depending on the particle size, the number concentration reduction percentage ranged from 48-100% for particles larger than 0.1 µm. Large droplets created by splashing were captured by the high-speed camera. Similar studies can be used for future particle aerodynamic studies. The fluorescein droplets deposited on the lid back sections, which were closer to the FOM accounted for 82% of the total fluorescein. Based on two-way ANOVA analysis, there were significant differences among both the experimental flushes (p = 0.0185) and the sections on the lid (p = 0.0146). Future work should explore the aerosolization produced by flushing and the performance of the lid in real restroom environments, where feces and urine exist in the bowl water and the indoor ventilation system is in operation.


Assuntos
Aparelho Sanitário , COVID-19 , Aerossóis/análise , COVID-19/prevenção & controle , Fluoresceínas , Humanos , SARS-CoV-2 , Água
4.
Nanomaterials (Basel) ; 12(4)2022 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-35214991

RESUMO

Millions of workers are occupationally exposed to volatile organic compounds (VOCs) annually. Current exposure assessment techniques primarily utilize sorbent based preconcentrators to collect VOCs, with analysis performed using chemical or thermal desorption. Chemical desorption typically analyzes 1 µL out of a 1 mL (0.1%) extraction volume providing limited sensitivity. Thermal desorption typically analyzes 100% of the sample which provides maximal sensitivity, but does not allow repeat analysis of the sample and often has greater sensitivity than is needed. In this study we describe a novel photothermal desorption (PTD) technique to bridge the sensitivity gap between chemical desorption and thermal desorption. We used PTD to partially desorb toluene from three carbonaceous substrates; activated carbon powder (AC-p), single-walled carbon nanotube (SWNT) powder (SWNT-p) and SWNT felts (SWNT-f). Sorbents were loaded with 435 ug toluene vapour and irradiated at four light energies. Desorption ranged from <0.007% to 0.86% with a single flash depending on substrate and flash energy. PTD was significantly greater and more consistent in SWNT-f substrates compared to AC-p or SWNT-p at all irradiation energies. We attribute the better performance of SWNT-f to greater utilization of its unique nanomaterials properties: high thermal conductivity along the nanotube axis, and greater interconnection within the felt matrix compared to the powdered form.

5.
J Emerg Manag ; 19(7): 193-202, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34723379

RESUMO

INTRODUCTION: Having an adequate supply of personal protective equipment during the COVID-19 pandemic has been a constant challenge for hospitals across the United States. In the event of shortages, our assembled mask might offer noninferior protection compared to an N95 respirator. OBJECTIVE: To study the ability of an assembled mask to pass a quantitative fit testing. METHODS: We conducted a feasibility study at the Oklahoma City Veteran Affairs Health Care System. Volunteers were fitted with an assembled mask made of either a Hans Rudolph half-face mask or a Respironics Performax full-face mask, attached to an Iso-Gard HEPA light Filter 28022 through a Performax SE elbow hinge. Quantitative fit testing was conducted using the Occupation Safety and Health Administration fit testing protocol. The primary outcome was the percentage of participants who pass the quantitative fit test. Secondary outcomes included the overall fit factor (FF), average FF for different exercises, changes in pulse oximetry and end-tidal CO2 at 0 and 15 minutes, willingness to use the mask, and visibility assessment. RESULTS: Twenty participants completed the study, and all (100 percent) passed the quantitative fit testing. The overall FF had a geometric mean of 2,317 (range: 208-16,613) and a geometric standard deviation of 3.8. The lowest FF was recorded while the subjects were talking. Between time 0 and 15 minutes, there was no clinically significant change in pulse oximetry and end-tidal CO2 levels. Most participants reported "very good" visibility and were "highly likely" to use the Hans Rudolph half-face mask in the case of shortage. CONCLUSION: Our assembled respirator offers noninferior protection to N95 respirators in the setting of hypothetical protective equipment shortage.


Assuntos
COVID-19 , Pandemias , Desenho de Equipamento , Estudos de Viabilidade , Humanos , Respiradores N95 , Pandemias/prevenção & controle , Equipamento de Proteção Individual , SARS-CoV-2 , Estados Unidos
6.
Phys Fluids (1994) ; 33(8): 085102, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34471340

RESUMO

The coronavirus disease 2019 pandemic has imposed unprecedented occupational challenges for healthcare professionals. In dentistry, handheld instruments such as air and electric handpieces, ultrasonic scalers, and air/water syringes are capable of generating aerosols, droplets, and splatter, thereby exposing dental professionals to airborne contaminants such as viruses, bacteria, and fungi. The objective of the present study was to determine the spatial distribution of aerosols by size (0.30 to 20.00 µm) and the efficacy of a novel aerosol containment device (ACD) in a large operatory room with 12 dental chairs. Real-time portable laser aerosol spectrometers were used to measure the size-resolved number concentration of aerosols generated by a collision nebulizer. Results reported demonstrate that aerosol number concentrations significantly decreased as a function of distance with or without the utilization of the ACD. The ACD was able to efficiently decrease (up to 8.56-fold) the number and size distribution of particles in a large dental clinic. The novel device demonstrated higher efficiency for particles shown to contain the highest levels of severe acute respiratory syndrome coronavirus 2 in Chinese hospitals, thereby showing great promise to potentially decrease the spreading of nosocomial pathogens in dental settings.

7.
Artigo em Inglês | MEDLINE | ID: mdl-34299985

RESUMO

Many types of electronic cigarettes (ECs) are currently in use, but the default flow rate used to simulate puffing is centered on tobacco cigarette flow rates. CORESTA offers several methods and technical guides for evaluation of ECs but there are few puffing topography studies focusing on sub-ohm ECs; differences between real-world usage and that found in the literature appear large. This study focuses on how power and flow rate affect the nicotine yield of a sub-ohm EC. A puffing system (Puff3rd) has been designed and used to produce and collect EC aerosol. Nicotine yield was measured by GC-MS at three power levels and four flow rates. Data analysis was conducted in SAS using the MIXED procedure. Power, flow rate, and their interaction were all significant predictors of nicotine yield. Nicotine yield increased with both the vaping power and the puff flow rate with significant interaction of the two. Findings indicate that using the current CORESTA flow rate (1100 mL/min) to evaluate third-generation ECs underestimates nicotine yield and likely overestimates pyrolysis products. Real users are expected to have 2-3× the nicotine dose measured at 1100 mL/min, which could confound epidemiological studies seeking to link nicotine delivery to product satisfaction and acceptability.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Vaping , Aerossóis , Nicotina , Pirólise
8.
J Environ Health Sci Eng ; 19(1): 805-817, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33875931

RESUMO

PURPOSE: Frontline health care workers (HCWs) must wear a standard N95 or FFP2 respirator during worldwide pandemics of respiratory diseases including COVID-19 to protect against airborne infectious pathogens when performing care activities. This study aimed to quantitatively investigate the fit of most of the common FFRs used during the COVID-19 pandemic in Iran. METHODS: A total of 37 volunteers were fit tested in 20 selected FFRs in a randomized order. The selected FFRs were underwent quantitative fit testing by PortaCount® model 8038. To determine the effects of face sizes on respirator fit, the participants' facial dimensions were measured using a digital caliper. RESULTS: The rate of passing fit tests for the studied FFRs were surprisingly low with 11 out of 20 FFRs having less than 10% passing fit tests and the best performers having only 43% and 27% passing fit tests (brands 2 and 20, respectively). Cup-shaped respirators provided significantly greater fit than the vertical flat-fold ones (p < 0.001). A significantly different FFs were found among the respirator brands (F = 13.60, p < 0.001). CONCLUSION: Overall, unacceptably low fit factors were obtained from the studied FFRs. The main reasons for this are suspected to single size and style for each studied FFR. It confirms the importance and requirement of the proper respirator selection in that way fitted optimally into facial dimensions, appropriate usage, and properly performing the fit testing procedure. A unique fit test panel should be developed to guide respirator wearers in selecting the appropriate FFR for their specific face sizes.

9.
ACS Omega ; 6(8): 5415-5422, 2021 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-33681581

RESUMO

Volatile organic compounds (VOCs) pose an occupational exposure risk due to their commonplace usage across industrial and vocational sectors. With millions of workers annually exposed, monitoring personal VOC exposures becomes an important task. As such, there is a need to improve current monitoring techniques by increasing sensitivity and reducing analysis costs. Recently, our lab developed a novel, preanalytical technique known as photothermal desorption (PTD). PTD uses pulses of high-energy, visible light to thermally desorb analytes from carbonaceous sorbents, with single-walled carbon nanotube buckypapers (BPs) having the best overall performance. To apply this new technology most effectively for chemical analysis, a better understanding of the theoretical framework of the thermal phenomena behind PTD must be gained. The objectives of the present work were 3-fold: measure the thermal response of BPs during irradiation with light; determine the best method for conducting such measurements; and determine the thermal conductivity of BPs. BPs were exposed to four energy densities, produced by light pulses, ranging from 0.28 to 1.33 J/cm2, produced by a xenon flash lamp. The resulting temperature measurements were obtained via fast response thermocouple (T/C) mounted to BPs by three techniques (pressing, adhering, and embedding). Temperature increase measured by T/C using the adhering and pressing techniques resulted in similar values, 29.2 ± 0.8 to 56 ± 3 °C and 29.1 ± 0.9 to 50 ± 5 °C, respectively, while temperature increase measured by embedding the T/C into the BP showed statistically larger increases ranging from 35.2 ± 0.9 to 76 ± 4 °C. Peak BP temperatures for each mounting technique were also compared with the temperatures generated by the light source, which resulted in embedded BPs demonstrating the most temperature conversion among the techniques (74-86%). Based on these results, embedding T/Cs into the BP was concluded to be the best way to measure BP thermal response during PTD. Additionally, the present work modeled BP thermal conductivity using a steady-state comparative technique and found the material's conductivity to be 10.6 ± 0.6 W/m2. The present work's findings will help pave the way for future developments of the PTD method by allowing calculation of the energy density necessary to attain a desired sorbent temperature and providing a means for comparing BP fabrication techniques and evaluating BP suitability for PTD before conducting PTD trials with analytes of interest. Sorbents with greater thermal conductivity are expected to desorb more evenly and withstand higher energy density exposures.

11.
Tob Control ; 2020 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-32404518

RESUMO

INTRODUCTION: The present study examined how the lack of characterising flavours and low levels of humectants may affect users' waterpipe tobacco (WT) smoking topography, subjective effects, toxicant exposure and intentions for continued use. METHODS: 89 WT smokers completed four ad libitum smoking sessions (characterising flavor/high humectant (+F+H); characterising flavor/low humectant (+F-H); no characterising flavor/high humectant (-F+H); no characterising flavor/low humectant (-F-H)) in a randomised cross-over design. WT was commercially available; same brand but nicotine levels were not held constant. A subsample (n=50) completed a standardised, 10-puff session preceding ad libitum smoking. Participants completed questionnaires, exhaled carbon monoxide (eCO) testing and provided blood samples for plasma nicotine. Smoking topography was measured throughout the session. Post hoc analyses showed that -F+H and -F-H did not differ significantly in humectant levels. Therefore, these groups were collapsed in analyses (-F-H). RESULTS: WT smokers reported significantly greater satisfaction, liking, enjoyment and greater intentions for continued use when smoking +F+H compared with other WT products, with -F-H receiving the lowest ratings. Significant differences in topography were observed during standardised and ad libitum sessions, with the -F-H preparation leading to greater total inhaled volume and eCO boost, but lower nicotine boost compared with +F+H (all p<0.05). DISCUSSION: The findings demonstrate the importance of flavours and humectants on improving WT smoking experience and increasing the likelihood that users will want to initiate and continue smoking. Moreover, it demonstrates that flavours and humectants influence smoking behaviour and toxicant exposure in some unexpected ways that are important for regulatory efforts.

12.
Inhal Toxicol ; 32(3): 110-114, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32279591

RESUMO

Objective: Electronic Cigarettes (EC) use continues to increase with many efforts underway to develop dose-response relationships for clinical and sub-clinical purposes. This study investigated the battery performance of several variable voltage (VV) ECs capable of varied voltage outputs.Materials and Methods: Six brands of VV EC batteries were tested for dial setting accuracy (voltage) and power supplied during simulated vaping. All measurements were conducted using a single atomizer with two different resistance coils at four voltage settings in a blocked randomized structure. Battery dial settings were accurate when disconnected from an atomizer.Results: When powering an atomizer during simulated vaping, all batteries supplied power linearly up to approximately 8.5 watts. Beyond 8.5 watts all batteries began to undersupply power, plateauing around 9-10 watts, depending on the specific battery.Discussion: This behavior was not consistent with battery internal resistance. Undersupply of power at higher device settings will result in lower-than-expected nicotine (or THC) delivery and potentially lower pyrolysis products such as aldehydes.Conclusion: Studies seeking to associate VV EC power with psychological, physiological or toxicological effects should measure the actual power supplied or else a negative bias is likely to be observed in trials above 8.5 watts.


Assuntos
Equipamentos e Provisões Elétricas , Sistemas Eletrônicos de Liberação de Nicotina , Vaping
13.
J Occup Environ Hyg ; 16(5): 349-354, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30870115

RESUMO

Nicotine from electronic cigarette aerosol will deposit on surfaces immediately after vaping, but how long deposited nicotine will persist on various surfaces is unknown. This work exposed glass and terrycloth (cotton) materials to electronic cigarette aerosols for 1 hr, assessed the initial nicotine sorption, and characterized surface persistence over a 72-hr period. Exponential decay of surface concentration was observed for both materials. Terrycloth had higher initial nicotine deposition and retained nicotine substantially longer than glass. Residual nicotine concentrations persisted on both surface types for 72 hr. Statistical modeling predicted surface concentrations to reach background levels after 4 and 16 days for glass and terrycloth, respectively. Nicotine persistence was long enough to pose a potential thirdhand nicotine exposure risk, and reactions to produce tobacco-specific nitrosamines may be possible from nicotine deposition from electronic cigarette aerosols, but further study is needed.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Nicotina/análise , Vaping , Aerossóis , Poluição do Ar em Ambientes Fechados/análise , Fibra de Algodão/análise , Exposição Ambiental/análise , Vidro/química , Nicotina/química
14.
PLoS One ; 13(12): e0210147, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30596800

RESUMO

INTRODUCTION: Electronic cigarettes (EC) have evolved rapidly toward higher powered devices that produce more vaping aerosol and a more satisfying vaping experience. This research characterized the particle size distribution and estimated the mass concentration of vaping aerosols produced at power outputs spanning the operating range typical of second generation variable voltage EC devices. METHODS: EC aerosol was characterized from a single coil atomizer powered by a variable voltage EC battery at the minimum and maximum dial settings (3.3, 11.2 Watts, W), and a lab controlled power supply (3-11.9 W). Aerosol particle size distribution was measured by a Scanning Mobility Particle Sizer and Aerodynamic Particle Sizer, spanning 16 nm to 19.8 µm. A mouth puff was simulated using a 100 mL glass syringe. RESULTS: Consistent with prior studies, sub-micron EC aerosol size distributions were bimodal, with peaks at 40 and 200 nm, however a previously unreported third mode was observed at approximately 1000 nm. The ~1000 nm mode accounted for 7-20x the aerosol mass of the smaller modes. Increasing atomizer power decreased count concentration of particles <600 nm but increased particle count >600 nm. Particle mass distribution shifted toward micron sized particles with increasing power and increased the respirable fraction of aerosol, likely due to increased coagulation and condensation around nano-sized particles. CONCLUSIONS: Vaping power greatly affects EC aerosol count and mass distribution. Mouth puffed EC aerosol spans a much wider particle size range than previously reported, although the major portion of the mass is still well within the alveolar size range the larger particles will deposit within the oro-pharyngeal cavity at 2-3x greater efficiency than in alveoli. These observations have major clinical implications, as aerosol particle size distribution determines deposition sites along the respiratory tract. The results of this experiment stress the need for further research to inform the design, regulation and use of e-cigarette products.


Assuntos
Aerossóis/química , Sistemas Eletrônicos de Liberação de Nicotina , Tamanho da Partícula , Vaping , Humanos , Nicotina/química
15.
Tob Control ; 27(3): 319-324, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28381414

RESUMO

INTRODUCTION: One possible reason for the rapid proliferation of waterpipe (WP) smoking is the pervasive use of flavoured WP tobacco. To begin to understand the impact of WP tobacco flavours, the current study examined the impact of a preferred WP tobacco flavour compared with a non-preferred tobacco flavoured control on user's smoking behaviour, toxicant exposure and subjective smoking experience. METHOD: Thirty-six current WP smokers completed two, 45-minute ad libitum smoking sessions (preferred flavour vs non-preferred tobacco flavour control) in a randomised cross-over design. Participants completed survey questionnaires assessing subjective smoking experience, exhaled carbon monoxide (eCO) testing, and provided blood samples for monitoring plasma nicotine. WP smoking topography was measured continuously throughout the smoking session. RESULTS: While participants reported an enhanced subjective smoking experience including greater interest in continued use, greater pleasure derived from smoking, increased liking and enjoyment, and willingness to continue use after smoking their preferred WP tobacco flavour (p values <0.05), no significant differences were observed in nicotine and carbon monoxide boost between flavour preparations. Greater average puff volume (p=0.018) was observed during the non-preferred flavour session. While not significant, measures of flow rate, interpuff interval (IPI), and total number of puffs were trending towards significance (p values <0.10), with decreased IPI and greater total number of puffs during the preferred flavour session. DISCUSSION: The current study is the first to examine flavours in WP smoking by measuring preferred versus control preparations to understand the impact on subjective experience, smoking behaviour and toxicant exposure. The pattern of results suggests that even this relatively minor manipulation resulted in significant changes in subjective experience. These results indicate a possible need for regulations restricting flavours in WP tobacco as with combustible cigarettes.


Assuntos
Testes Respiratórios , Monóxido de Carbono/análise , Exposição por Inalação/análise , Nicotina/sangue , Fumar/psicologia , Tabaco para Cachimbos de Água/efeitos adversos , Adolescente , Adulto , Comportamento do Consumidor , Feminino , Aromatizantes , Humanos , Masculino , Fumar/sangue , Adulto Jovem
16.
J Occup Environ Hyg ; 15(4): 334-340, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29283316

RESUMO

BACKGROUND: OSHA regulations state that an employer shall not permit tight-fitting respirators to be worn by employees who have facial hair that comes between the skin and facepiece seal. Studies have shown that facial hair in the face seal zone can increase penetration and decrease the fit factor (FF), although the relationship between the amount and characteristics of facial hair and the increase in penetration is not well quantified. This article examines the influence of facial hair length, areal density, and coarseness on FF for one model of half-face elastomeric negative-pressure air purifying respirator. APPROACH: Quantitative fit tests (QNFT) were performed on 19 subjects with beards initially 0.500-in long and subsequently trimmed to 0.250, 0.125, and 0.063 in, then after a razor shave. Three fit tests were performed at each of the 5 lengths, for 285 total tests. The average diameter and areal density of cheek and chin hair were measured. Penetration was modeled as a function of hair length category, beard areal density, and hair coarseness. RESULTS: FF decreased with beard length, especially beyond 0.125 in. However, passing FF scores were achieved on all tests by all subjects at the smooth shave and 0.063 in conditions, and 98% of tests were passed at 0.125 in; seven subjects passed all tests at all conditions. Chin and cheek areal densities were significantly different and were only weakly correlated. Beard hair diameters were normally distributed across subjects (mean 76 µm, standard deviation 7.4 µm). Beard length and areal density, but not coarseness, were statistically significant predictors of fit using an arcsine transformed penetration model. FF decreased with increasing beard length, especially beyond 0.125 in, although FF with a "stubble" beard did not differ significantly from a smooth shave. FF also decreased with increasing areal beard hair density. CONCLUSION: Beard length and areal density negatively influence FF. However, tight-fitting half-face negative-pressure respirator fit tests can achieve adequate fit factor scores even with substantial facial hair in the face seal area.


Assuntos
Face , Cabelo , Dispositivos de Proteção Respiratória , Adolescente , Adulto , Idoso , Remoção de Cabelo , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto
17.
PLoS One ; 12(5): e0177780, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28542301

RESUMO

BACKGROUND: Electronic cigarette (EC) aerosols contain unique compounds in addition to toxicants and carcinogens traditionally found in tobacco smoke. Studies are warranted to understand the public health risks of ECs. OBJECTIVE: The aim of this study was to determine the genotoxicity and the mechanisms induced by EC aerosol extracts on human oral and lung epithelial cells. METHODS: Cells were exposed to EC aerosol or mainstream smoke extracts and DNA damage was measured using the primer anchored DNA damage detection assay (q-PADDA) and 8-oxo-dG ELISA assay. Cell viability, reactive oxygen species (ROS) and total antioxidant capacity (TAC) were measured using standard methods. mRNA and protein expression were evaluated by RT-PCR and western blot, respectively. RESULTS: EC aerosol extracts induced DNA damage in a dose-dependent manner, but independently of nicotine concentration. Overall, EC aerosol extracts induced significantly less DNA damage than mainstream smoke extracts, as measured by q-PADDA. However, the levels of oxidative DNA damage, as indicated by the presence of 8-oxo-dG, a highly mutagenic DNA lesion, were similar or slightly higher after exposure to EC aerosol compared to mainstream smoke extracts. Mechanistically, while exposure to EC extracts significantly increased ROS, it decreased TAC as well as the expression of 8-oxoguanine DNA glycosylase (OGG1), an enzyme essential for the removal of oxidative DNA damage. CONCLUSIONS: Exposure to EC aerosol extracts suppressed the cellular antioxidant defenses and led to significant DNA damage. These findings emphasize the urgent need to investigate the potential long-term cancer risk of exposure to EC aerosol for vapers and the general public.


Assuntos
Antioxidantes/metabolismo , Dano ao DNA , Sistemas Eletrônicos de Liberação de Nicotina/efeitos adversos , Estresse Oxidativo/efeitos dos fármacos , Estresse Oxidativo/genética , Aerossóis , Linhagem Celular , Relação Dose-Resposta a Droga , Humanos , Fumaça/efeitos adversos , Fatores de Tempo
18.
J Occup Environ Hyg ; 14(7): 523-533, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28406364

RESUMO

3-D printing is an additive manufacturing process involving the injection of melted thermoplastic polymers, which are then laid down in layers to achieve a pre-designed shape. The heated deposition process raises concerns of potential aerosol and volatile organic compounds (VOC) emission and exposure. The decreasing cost of desktop 3-D printers has made the use of 3-D printers more acceptable in non-industrial workplaces lacking sufficient ventilation. Meanwhile, little is known about the characteristics of 3-D printing fume emission. The objective of this study was to characterize aerosols and VOC emissions generated from various filaments used with a low-cost 3-D printer in an environmental testing chamber. A pre-designed object was printed in 1.25 hours using eight types of filaments. A scanning mobility particle sizer and an aerodynamic particle sizer were employed to measure the particle size distribution in sub-half-micron fraction (<0.5 µm) and super-half-micron fraction (0.5-20 µm), respectively. VOC concentration was monitored real-time by a photoionization detector and sampled with a tri-sorbent thermal desorption tube, and analyzed by thermal desorption gas chromatography mass spectrometry (TD-GC/MS). Results showed high levels of fume particles emission rate (1.0 × 107 to 1.2 × 1010 #/min) in the sub-half-micron range with mode sizes of 41-83 nm. Particle concentrations peaked during the heat-up and solid layer printing periods. Total VOC concentration in the chamber followed a first-order buildup, with predominant VOC species in the chamber were breakdown and reaction products of the filaments, such as styrene from ABS filaments. These findings and exposure scenario estimation suggest that although the VOC concentrations were much lower than occupational exposure limits, particles with size less than micron might be a concern for users of low-cost 3-D printers due to high respirablity, especially if used in settings without proper guidance and engineering control.


Assuntos
Aerossóis/análise , Poluição do Ar em Ambientes Fechados/análise , Impressão Tridimensional , Compostos Orgânicos Voláteis/análise , Monitoramento Ambiental/métodos , Tamanho da Partícula , Polímeros/química
19.
Ann Work Expo Health ; 61(3): 311-320, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28355418

RESUMO

Plasma cutting is a metal fabrication process that employs an electrically conductive plasma arc to cut metals. The metal fume emitted from stainless steel plasma cutting may consist of hexavalent chromium (Cr6+), which is a carcinogen, and other toxicants. Overexposure to plasma cutting fume may cause pulmonary toxicity and other health effects. This study was to evaluate the effects of operation parameters (arc current and arc time) on the fume formation rates, Cr6+ and other oxides concentrations, particle size distributions (PSD), and particle morphology. A fume chamber and high-volume pump were used to collect fume produced from cutting ER308L stainless steel plates with arc currents varying between 20 and 50 A. The amount of fume collected on glass fiber filters was gravimetrically determined and normalized to arc time. Cr6+ and other oxides in the fume were analyzed using ion chromatography. PSD of the fume was examined using a scanning mobility particle sizer and an aerodynamic particle sizer for fine and coarse fractions, respectively. The particle morphology was imaged through a transmission electron microscope (TEM). Total fume generation rate increased with arc current and ranged from 16.5 mg min-1 at 20 A to 119.0 mg min-1 at 50 A. Cr6+ emissions (219.8-480.0 µg min-1) from the plasma cutting were higher than welding fume in a previous study. Nitrogen oxides level can be an indicator of oxidation level and Cr6+ formation (R = 0.93). Both PSD measurement and TEM images confirmed a multimodal size distribution. A high concentration of a fine fraction of particles with geometric mean sizes from 96 to 235 nm was observed. Higher arc current yielded more particles, while lower arc current was not able to penetrate the metal plates. Hence, the worker should optimize the arc current to balance cut performance and fume emission. The findings indicated that arc current was the dominant factor in fume emission from plasma cutting. Appropriate ventilation and respiratory protection should be used to reduce workers' exposure.


Assuntos
Poluentes Ocupacionais do Ar/análise , Carcinógenos Ambientais/análise , Cromo/análise , Exposição Ocupacional/prevenção & controle , Material Particulado/análise , Aço Inoxidável , Soldagem/métodos , Poeira/análise , Gases/análise , Humanos , Óxidos/análise , Tamanho da Partícula
20.
Tob Control ; 26(e1): e23-e28, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27729564

RESUMO

INTRODUCTION: Electronic cigarettes' (e-cigarettes) viability as a public health strategy to end smoking will likely be determined by their ability to mimic the pharmacokinetic profile of a cigarette while also exposing users to significantly lower levels of harmful/potentially harmful constituents (HPHCs). The present study examined the nicotine delivery profile of third- (G3) versus second-generation (G2) e-cigarette devices and their users' exposure to nicotine and select HPHCs compared with cigarette smokers. METHODS: 30 participants (10 smokers, 9 G2 and 11 G3 users) completed baseline questionnaires and provided exhaled carbon monoxide (eCO), saliva and urine samples. Following a 12-hour nicotine abstinence, G2 and G3 users completed a 2-hour vaping session (ie, 5 min, 10-puff bout followed by ad libitum puffing for 115 min). Blood samples, subjective effects, device characteristics and e-liquid consumption were assessed. RESULTS: Smokers, G2 and G3 users had similar baseline levels of cotinine, but smokers had 4 and 7 times higher levels of eCO (p<0.0001) and total 4-(Methylnitrosamino)-1-(3-pyridyl)-1-butanol (i.e., NNAL, p<0.01), respectively, than G2 or G3 users. Compared with G2s, G3 devices delivered significantly higher power to the atomiser, but G3 users vaped e-cigarette liquids with significantly lower nicotine concentrations. During the vaping session, G3 users achieved significantly higher plasma nicotine concentrations than G2 users following the first 10 puffs (17.5 vs 7.3 ng/mL, respectively) and at 25 and 40 min of ad libitum use. G3 users consumed significantly more e-liquid than G2 users. Vaping urges/withdrawal were reduced following 10 puffs, with no significant differences between device groups. DISCUSSION: Under normal use conditions, both G2 and G3 devices deliver cigarette-like amounts of nicotine, but G3 devices matched the amount and speed of nicotine delivery of a conventional cigarette. Compared with cigarettes, G2 and G3 e-cigarettes resulted in significantly lower levels of exposure to a potent lung carcinogen and cardiovascular toxicant. These findings have significant implications for understanding the addiction potential of these devices and their viability/suitability as aids to smoking cessation.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Nicotina/administração & dosagem , Fumar/metabolismo , Produtos do Tabaco , Adulto , Monóxido de Carbono/metabolismo , Cotinina/análise , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nicotina/metabolismo , Saliva , Fumantes , Inquéritos e Questionários , Fatores de Tempo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...